Then remove the harness (1) from the oil dual level float switch (2)
by disconnecting the plug connector 3W107-P8 (5) from the switch
receptacle J8 (6). Now remove the harness from the harness from the
100 amp relay (3) by removing the two nuts (7), lockwashers (8),
washers (9), and terminal lugs (10) from the relay terminals 21 and
X2 (11).
To complete the disconnecting the harness, you must
disconnect plug connector 3W107-P16 (12) from the exciter receptacle
Figure 1-44. Maintenance Indicator Branched Wiring
Harness 3W107, Second View.
Now you can remove the harness (1) from the engine oil pump assembly
(2) by disconnecting plug connector 3W107-P30 (3) from the oil
pressure-thermal switch receptacle connector J30 (4), disconnecting
plug connector 3W107-P7 (5) from the pressure filter bypass switch
receptacle connector 57 (6), and disconnecting plug connector 3W107-
P9 (7) from the oil temperature receptacle J9 (8). The you lift the
36
OD1707