Next you must remove the harness (1) from the temperature rotor
sensor (2) by disconnecting plug connector 3W105-P34 (5) from the
temperature rotor sensor receptacle connector J34 (6).
Now
disconnect the tube nut (8) from the tube tee (9) on the pressure
fluid filter (10), pull the tube (11) away from the tee, remove the
the pressure fluid double angle bracket (3) (cut off any electrical
tiedown straps (7) as necessary). Disconnect the electro-mechanical
system (4) plug connector 3W105-P33 (13) from the fuel system
receptacle connector J33 (14) (fig. 1-47).
To complete this removal process, remove the screw (15) and self-
locking nut (16) from the loop clamp (17) and remove the loop clamp.
Then disconnect plug connector 3W105-P37 (18) from the receptacle
connector 3W105-1-J37 (19) and lift the wiring harness from the
powerpack (fig. 1-47).
Figure 1-47.
Fuel Maintenance System Branched Wiring
Harness 3W105, Second View.
38
OD1707