CAUTION
Nipple (17) will be damaged during removal.
DO NOT remove
unless necessary.
Figure 13.
Disassembly and Assembly.
o Remove the five screws (18) and CAREFULLY remove the liquid level
transmitter (19) and gasket (20) from the reservoir (11). Remove
the six screws (21) and lockwashers (22), and CAREFULLY remove
the temperature transmitter housing (23) and gasket (24).
o Unscrew the housing cap (25) from the temperature transmitter
housing (23) and disconnect the electrical lead 12332686 (26)
from the temperature transmitter (27). Unscrew the transmitter
(27) and remove it from the housing (25). Remove the four screws
(28) and lockwashers (29) that secure the connector lead (26) and
gasket (30) to the housing (23). Remove the lead (26) and gasket
(30) from the housing (23).
21
OD1703