> Figure 31. Crew AFES T/A Panel and SCEA.
Test Alarm Panels. Standard Control Electronic Amplifier
Figure 32. Engine AFES Remote Status Indicator.
Maintenance of the Automatic Fire Extinguisher System (AFES), M992
Page Navigation
44
45
46
47
48
49
50
51
52
53
54
WARNING
Turn crew T/A panel
MAINTenance
switch to horizontal
position.
Remove
locking pins from valve actuator
guards of crew extinguisher cylinder bottles no. 3 and
no. 4.
Remove
anti-recoil plugs from discharge ports
and replace with
dispersion
nozzles.
Figure 31.
Crew
AFES
T/A Panel and
SCEA.
The removal/installation of the engine
AFES
remote status indicator is the
fourth and last Item to be addressed in this portion of the subcourse. You
will perform this task by using Figure 31 and the procedures listed below.
WARNING
Turn the engine T/A panel
MAINTenance
switch to the
vertical position.
Make
sure the locking pin is
installed in the actuator guard of the engine
extinguisher cylinder bottle no. 1 and install the
locking pin in the valve actuator guard of the engine
extinguisher cylinder bottle no. 2.
49
OD1700