Next position the harness on the duct (1) and under the two
straps (2), and install the two screws (3), new lockwashers
(4), and washers (5) to one side of the duct and straps.
Install new straps (6) on the harness as required (fig. 1-24).
Figure 1-24. Maintenance Indicator Branched Wiring
Harness (3W107), Third View.
Install the Thermocouple Branched Wiring Harness (3W106). Lay
the harness (1) on the powerpack so the three connectors (2)
are near their mating connectors (3) and screw the connectors
(2 and 3) together. Then position the harness on the duct (5)
and under the two straps (6), and install the two screws (7),
new lockwashers (8), and washers (9) to one side of the duct
(5) and straps (6).
Use new straps (4) on the harness as
required (fig. 1-25).
Figure 1-25.
Thermocouple Branched Wiring Harness (3W106).
23
OD1708