connector (Fig. 37). Place the conveyor control switch to the OUT position
and check the continuity with a multimeter.
If the multimeter remains on
infinity, lead AAB between the conveyor control switch and the hydraulic
control panel and gage panel connector must be replaced.
However, the
multimeter indicated 0 ohms, you must connect the lead, assemble the
hydraulic gage panel, and continue to troubleshoot the system.
Figure 37.
o Disconnect the harness connector from the conveyor directional control valve.
Check the continuity of the lead using a multimeter by placing the red probe
of the multimeter in the gage panel connector socket A and the black probe in
If the multimeter remains on
infinity, lead AAA between the hydraulic control panel connector and conveyor
directional control valve is defective and you must notify support
maintenance. However, the multimeter indicated 0 ohms and you must continue
to troubleshoot the system.
o Place the red probe of the multimeter in connector socket C and the black
lead using a multimeter.
If the multimeter remains on infinity, lead AAB
between the hydraulic control panel connector and conveyor directional
control valve is defective and you must notify support maintenance. However,
the multimeter indicated 0 ohms, connect the lead, and you must continue to
troubleshoot the system.
41
OD1737