M2/M3 BFV: HULL POWER DIST SYSTEM - OD1606 - LESSON 1/TASK 1
With plug 3W4P1 disconnected, remove the nut (4) (figure 10), lock
washer (5), lead 3W4E2 (1) and ground lead 3W5B2 (2) from terminal
3A2G1E1 (6) on the generator. Discard the lock washer.
With the electrical leads disconnected, remove the four locknuts (8)
(figure 11 on the following page), and washers (9) from the studs
(10).
Discard the locknuts.
studs and remove from the power take off (PTO) (7).
Once the
generator has been removed from the PTO, remove the splined shaft
(11) (figure 12 on the following page) from the generator drive (12)
in the generator (3).
FIGURE 10.
REMOVING LEADS 3W4B2 AND 3W5E2.
Now remove the preformed packing (13) (figure 13 on the page 15) from
adapter (14) and discard the preformed packing.
This completes the generator removal procedures.
In the paragraphs
that follow, the procedures for installing the generator will be
covered.
While reading through these paragraphs, refer back to
figures 6 thru 13 on pages 11 through 15.
13