Figure 11.
(17) Connect a Jumper wire from pin C of receptacle A to pin A of
receptacle B. Indicator light A should illuminate only when switch B is in RUN
position.
(18) Connect a Jumper wire from pin C of receptacle A to pin C of
receptacle B. Indicator light A should remain illuminated when switch B is in RUN,
START, and OFF positions.
(19) Connect a Jumper wire from pin C of receptacle B to pin E of
receptacle B. Test set fuel pump should operate.
(20) Place CIRCUIT SELECTOR switch in C position.
(21) Place test set switch C in HI position and then in LO position.
Fuel pump should operate when switch is in either position.
(22) Connect a Jumper wire from pin C of receptacle C to pin A of
receptacle C. Indicator light C should remain illuminated when switch C is in HI,
LO, and OFF positions.
(23) Connect a Jumper wire from pin C of receptacle C to pin B of
receptacle C. Indicator light C should illuminate only when switch C is in HI or
LO position.
(24) Connect a Jumper wire from pin C of receptacle C to pin D of
receptacle C. Indicator light C should illuminate only when switch C is in HI
position.
OS 010, 8-P14