(25) Place CIRCUIT-SELECTOR switch in D position.
(26) Place test set RUN-OFF-START switch D in START position.
Fuel pump
should operate only when switch is in this position.
(27) Connect a Jumper wire from pin E of receptacle D to pin B of
receptacle D. Indicator light D should illuminate only when RUN-OFF-START switch D
is in START. or RUN position and HI-LO switch D is in HI position.
(28) Connect a Jumper wire from pin E of receptacle D to pin C of
receptacle D. Indicator light should illuminate only when RUN-OFF-START switch is
in START position.