M2/M3 BFV: TROUBLESHOOTING - OD1610 - LESSON 2/TASK 1
FIGURE 9.
CONTROLLABLE INTERFACE ASSEMBLY.
(4) Test Cables and Adapters. The test cables and adapters assembly
(figure 10 on the following page) consists of a shorting plug, cable
assemblies, and an adapter for vehicle testing.
c. Preparing the STE for Operation.
Before the STE can be used
effectively, it must be inspected and hooked up to the vehicle. A self-test
must then be performed to ensure the STE is working properly. For the self-
test to succeed, the test set must be operated in a temperature environment
between +20 and +125 Fahrenheit.
An internal temperature sensing device
stops the operation of the test set outside these temperature limits. Any
component that cannot be repaired by straightening bent pins, or by
cleaning, should be turned in for replacement.
57