M2/M3 BRADLEY FIGHTING VEHICLE: TURRET - OD1609 LESSON 3/TASK 3
FIGURE 33.
CONNECTIONS 2W302P7/2A200J2 AND 2W301P1/2A200J1.
(b)
Manually traverse the turret to 6400 mils (TM 9-2350-252-10-2) and remove
the integrated sight unit (ISU)(TM 9-2350-252-20-2-3, page 21-57).
Inspect
connection 2W302P3 to 2A203J3.
(c)
Remove right turret floor plate (TM 9-2350-252-20-2-2, page 4-22).
Check
connection 3W301P4 to 2A1J4.
(3)
Repeating Test 2640.
When all of the connections have been checked and
tightened, if needed, test 2640 should be repeated in hopes of obtaining a NO
FAULTS FOUND condition. Before repeating the test, it may be necessary to connect
some components disconnected during testing (i.e., if disconnection was required by
the SETCOM instructions).
If required, move the MASTER POWER switch to OFF,
manually traverse the turret to 3200 mils (TM 9-2350-252-10-2), and install plug
2W202P1 on jack 2A200J4 (figure 34 on the following page).
Reinstall the ISU (TM 9-2350-252-20-2-3, page 21-43) and install the cap on the
diagnostic panel jack J3. Finally, manually traverse the turret to 6400 mils.
144