o Disconnect the 24 vdc terminal, place the red probe of the
multimeter on the incoming terminal, and ground the black probe.
Set the MASTER switch to the ON position and test for voltage
(Fig. 67). If no voltage is indicated, you must notify support
maintenance. Assume that voltage was indicated, set the MASTER
switch to the OFF position, connect the 24 vdc terminal, and
continue to troubleshoot the system.
Figure 67.
Stacker 24 VDC Test Point.
o Test the stacker cable connector by placing the red probe of the
multimeter in socket B and grounding the black probe. Set the
MASTER switch to the ON position and test for voltage (Fig. 68).
If no voltage is indicated, repair or replace the cable. Assume
that voltage was indicated, set the MASTER switch to the OFF
position, and continue troubleshooting.
Figure 68.
Stacker Cable Connector.