M2/M3 BFV: TROUBLESHOOTING - OD1610 - LESSON 2/TASK 1
(f) Checking CIB Cable CX305. After it has been determined that
cable CX304 is okay, a similar test must be performed to check cable CX305
(figure 14). To perform this test, proceed as follows.
Press the GO key.
CONNECT CX305 TO CIB J2 should appear on the display.
Plug the CX305-P2 connector into the J2 connector on the CIB. Remember to
be careful when making the connection. The connector pins can be bent or
broken. Now press the GO key. The message CONNECT PLUG TA301 TO CX305 will
appear. Plug the TA301 plug into the CX305-P1 connector, being careful not
to bend or break any connector pins.
Once again, press the GO key.
The
message should be TEST IN PROGRESS PLEASE WAIT.
Wait for the display to change. One of two messages will appear. If the
message displayed is REMOVE PLUG TA301 FROM CX305, no problem has yet been
found. When this is the case, continue the self-test of cable CX305. If
the message REMOVE CX305 FROM CIB J2 appears, a problem has been detected.
When this is the case, proceed as follows.
FIGURE 14.
TESTING CIB CABLE CX305.
72