M2/M3 BFV: TROUBLESHOOTING - OD1610 - LESSON 2/TASK 1
Substituting cable CX305 for CX304 in this way will help the test set to
determine whether the faulty component is cable CX304 or TA301.
Plug the
CX305-P2 connector into the J2 connector on the CIB. Remember to make the
connection carefully because the pins can be bent or broken.
6
With cable CX305 connected to J2 on the CIB, press the GO
key.
CONNECT PLUG TA301 TO CX305 should appear on the display.
Connect
plug TA301 to connector CX305-P1.
7 Press the GO key.
The message TEST IN PROGRESS PLEASE WAIT
should appear on the display.
8 Wait for the display to change.
If the message FAULTY
TA301 appears on the display, replace TA301 and repeat the self-test.
If
the message FAULTY CX304 appears on the display, replace cable CX304 and
repeat the self-test.
If the self-test did not detect any problems with cable CX304, and the
message REMOVE PLUG TA301 FROM CX304 appeared on the display, plug TA301 is
removed from cable CX304. In this case, the next step is to press the GO
key. The message TEST IN PROGRESS PLEASE WAIT should appear on the display.
Wait for the display to change. If display reads CX304 OK, the self-test
has detected no problems in cable CX304.
In this case, proceed to test
cable CX305, as discussed in paragraph 3e(2)(f) on the following page.
However, if the message REMOVE CX304 FROM CIB J1 appears on the display, a
problem exists. To isolate the problem, follow these steps:
9 Press the GO key.
The message REMOVE CX304 FROM CIB J1
should appear. Remove CX304 from connector J1 on the CIB.
10 Press the GO key again.
The
message TEST
IN
PROGRESS
PLEASE WAIT should appear on the display.
11 Wait for the display to change.
If the message that
appears on the display reads FAULTY CX304, replace cable CX304 and repeat
the self-test.
If the message FAULTY CIB appears, replace the CIB, in
accordance with TM 9-4910-751-14-1, and repeat the self-test.
71