Checking for a Fault Message.
These steps of the self-test involve
several components of the test set.
Continue the self-test by performing these
steps:
Step 1.
Press the GO key.
The message displayed should read: INSPECT CIB
CONNECTORS J1 AND J2.
Step 2.
Press the GO key again. The message will be: ARE PINS BENT OR BROKEN?
Look at the connectors J1 and J2 on the CIB. Check for bent or broken pins. If no
pins are bent or broken, continue the test. If any pins on the CIB connectors J1
and 32 are bent or broken, proceed as follows:
(a)
Press the YES key.
The display reads: FAULTY CONNECTOR 66610 (the number
on the display is not used).
(b)
Press the STOP key.
(c)
Press the CLEAR key.
(d)
Replace the CIB, in accordance with TM 9-4910-751-14-1, chapter 5.
(e)
Repeat the self-test to this point.
Step 3.
If no pins on connectors J1 and J2 of the CIB are bent or broken, press
the NO key. The display will read: TEST IN PROGRESS PLEASE WAIT.
Step 4.
Wait for the display to change. If the display has no fault message,
it will read CONNECT CX304 TO CIB J1. When no fault message appears, the self-test
should continue with the CIB cable CX304 test. If a fault message appears on the
display, it will be necessary to take appropriate corrective action.
Table 1 on
the following page shows the faults that may appear on the display at this point.
115