23) to TRIPPED OFF.
(2) Remove the AC power cable assembly (figure 1-9, item 2)
from the PWR jack (figure 1-9, item 26).
(3) Remove the LR Tester from the base.
(4) Connect the AC power cable assembly on the PWR jack.
(6) Connect the oscilloscope ground lead to the ground terminal
(figure 1-9, item 11).
(7) Connect a probe to the channel A input connector on the
oscilloscope.
(8) Set the MODE switch (figure 1-9, item 17) to RCVR 1 PULSE.
(9) Touch the channel A probe to TP2 (figure 1-19).
(10) The waveform should be as shown in figure 1-20, part A.
(11) Set the ON/TRIPPED OFF circuit breaker to TRIPPED OFF.
(12) Remove the probes from the test point and the ground
terminal.
b. Two-Targets, One-Shot Pulse Check.
23) to TRIPPED OFF.
(2) Remove the AC power cable assembly (figure 1-9, item 2)
from the PWR jack (figure 1-9, item 26).
(3) Remove the LR Tester from the base.
(4) Connect the AC power cable assembly on the PWR jack.
(6) Connect the oscilloscope ground lead to the ground terminal
(figure 1-9, item 11).
(7) Connect a probe to the channel A input connector on the
oscilloscope.
(8) Set the MODE switch (figure 1-9, item 17) to RCVR 1 PULSE.
(9) Touch the channel A probe to TP3 (figure 1-19).
(10) The waveform should be as shown in figure 1-20, part B.
(11) Set the ON/TRIPPED OFF circuit breaker to TRIPPED OFF.
(12) Remove the probes from the test point and the ground
terminal.
27
OD1716