131
Para 11a(1)
133
CORRECT. Due to the low resistance of the stator winding a check
can be done, but it will have no practical value since all the coils
are connected in series.
134
Para 6d(5)
136
CORRECT.
The drive assembly is located on the armature splined end.
138
CORRECT. The rectifiers may be damaged if the output voltage
exceeds 32 volts.
139
Para 4d
140
CORRECT. The last operator of the test stand should have checked
the gearcase oil level. He may be in the process of correcting
the situation; if not, he has ignored the preventive maintenance
task.
141
CORRECT.
The reverse current relay disconnects the battery circuit.
142
CORRECT. The total resistance of 50,000 ohms will allow a current
flow of 50 microamperes when 2.5VDC is applied.
143
CORRECT. The three-phase AC generator has phase voltages that are
1200 apart in time.
144
CORRECT.
DC power or 120 volts, 60 Hz, single-phase power may be
used.
145
Para 5b(3)
147
CORRECT. If the diameter of the generator pulley is the same as the
drive pulley, then the RPM of the test stand will be the RPM of the
generator.
149
Restudy figure 5, the lubrication chart.
150
CORRECT.
Most starter motors are series wound.
152
Para 13
154
Para 4d(2)
156
Para 2h
157
Para 4a
159
CORRECT.
Brushes are only cleaned with a dry cloth.
161
Para 2c
163
Para 4b
164
Para 3c(2)
166
Para 3c
167
CORRECT. The spline adapter mates the coupling shaft to the
generator.
2