M2/M3 BFV: TROUBLESHOOTING - OD1610 - LESSON 1/TASK 2
NOTE
For quality control, the supervisor or a designated
representative checks all corrected status symbol X
faults.
The inspector then initials in column e, in
place of the person who performed the repair.
The
mechanic, however, initials over the status symbol in
column b.
When all faults that can be repaired are fixed, the DA Form 2404 goes to the
maintenance supervisor.
He checks those faults still not repaired and
decides what other action is done.
Faults that need support maintenance are recorded on a DA Form 2407.
Print
"DA Form 2407 (SPT)" in column d.
h. DA Form 2404 DEF MAINT (see figure 7 on the following page).
(1) Block 1 - Organization.
The name of the owning unit is entered
here.
(2) Block 2 - Nomenclature and Model.
The noun abbreviation and
model of the equipment go in block 2; enter the noun abbreviation and hull
design number for floating equipment.
(3) Block 3 - Registration/Serial/NSN.
The serial, registration, or
DA hull number goes in block 3.
(4) Blocks 4a and 4b are left blank.
(5) Block 5 is left blank.
(6) Block 6 - Type Inspection. Enter "Deferred Maintenance" in block
6.
The abbreviation "DEF MAINT" is an acceptable entry.
(7) Blocks 7 through 10 are left blank.
(8) Column a - TM Item Number.
Enter the date the fault was found in
column a.
40