M2/M3 BFV: FIRE CONTROL SYSTEM - OD1608 - LESSON 2/TASK 1
CAUTION
Be careful when connecting cable CX304 to the
CIB.
The connector pins are easily bent or
broken.
(a) The SETCOM display should read CONNECT CX304 TO CI0 J1.
Plug in connector CX304-P2 to the J1 connector on the CIB.
CAUTION
Be careful when connecting plug TA301 to cable
CX304.
The connector pins are easily bent or
broken.
(b) Press the GO key.
The display will show: CONNECT PLUG
TA301 TO CX304. Plug the TA301 plug into the CX304-P] connector.
(c) Press the GO key.
The words TEST IN PROGRESS PLEASE WAIT
will appear on the display.
(d) Wait for the display to change.
If the self-test does
not detect any problems, the display will change to read REMOVE PLUG
TA301 FROM CX304.
When this is the case, remove plug TA301 from
cable CX304 and continue with the self-test.
If the display reads
REMOVE CX304 FROM CIB J1, there is a problem in the system.
When
this message is received, perform the following steps to isolate the
defective component:
1 Press the GO key.
The display should read REMOVE
CX304 FROM CIB J1.
Unplug the
CX304-P2 connector from the J1
connector on the CIB.
2 Press the GO key.
CONNECT CX304 TO CIB 32 should
appear on the display.
Plug the CX304-P2 connector into the J2
connector on the CIB.
CAUTION
Be careful when connecting CX304 to the CIB.
The
connector pins are easy to break.
80