  7    8    9    10    11  12  13    14    15    16    17  

organizational level maintenance and troubleshooting procedures are
discussed below.
Figure  1-8  lists  the  tools  and  test  equipment  necessary  and
prescribed for use at the organizational level for the LR Test Set.
a. Painting.  Painting of the LR Test Set consists of touching up
damaged areas (refer to TB 43-0118).  Paints and finishes are listed
in SB 11-573.  The following procedures are applicable:
CAUTION
Do  not  paint  over  stenciling,
labels,
warning
notices, or the optical windows.

Combination case.
--
Lightly sand area requiring touchup.
--
Apply two thin coats of gray enamel per MIL-E-15090.

Control panel rivet heads.
--
Lightly sand rivet heads requiring touchup.
--
Apply
two
thin
coats
of
black
epoxy-polyamide,
MIL-C-22750 class 1, color 37038 FED-STD-595.

Adapter cable threaded cap.
--
Lightly sand area on cap requiring touchup.
Apply a
thin pretreatment coating (dry film) per MIL-C-81773,
color 37038, FED-STD-595.
b. Cleaning.
Clean the optical windows of the LR Test Set as
follows:
WARNING
The lens cleaning compound is poisonous
if taken internally.