Checking CIB Cable CX305
Ending the Self-Test.

M2/M3 Bradley Fighting Vehicle: Turret
Page Navigation
  116    117    118    119    120  121  122    123    124    125    126  

M2/M3 BRADLEY FIGHTING VEHICLE: TURRET - OD1609 LESSON 3/TASK 1
FIGURE 23.
TESTING CIB CABLE CX305.
Step 4.
Wait for the display to change.  One of two messages will appear.  If
the message displayed is REMOVE PLUG TA301 FROM CX305, no problem has yet been
found.
When this is the case, continue the self-test of cable CX305.
When the
message REMOVE CX305 FROM CIB J2 appears, a problem has been detected.  When this
is the case, proceed as follows:
(a)
When the message REMOVE CX305 FROM CIB J2 appears, remove cable CX305
from connector J2 on the CIB.
(b)
Press the GO key.
The message CONNECT CX305 TO CIB J1 will appear.
Connect CX305-P2 to connector J1 on the CIB.
(c)
Press the GO key.
The message TEST IN PROGRESS PLEASE WAIT will appear
on the display.
(d)
Wait for the display to change.  When a message appears, it will read one
of two things.
If the message says FAULTY CX305, replace cable CX305 and repeat
the self-test.
If the message reads FAULTY CIB, replace the CIB, in accordance
with TM 9-4910-751-14-1, then repeat the self-test.