• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print

Home > Ordnance Documents and other related manuals > > Figure 33. The Fire Suppression Bottle Jack 1L2J1
Pathway  Three.
Figure 34. The Diagnostic Panel

The M2/M3 Bradley Fighting Vehicle: Fire Suppression System
Page Navigation
  45    46    47    48    49  50  51    52    53    54    55  

M2/M3 BFV: FIRE SUPPRESSION SYST - OD1607 - LESSON 2/TASK 2
FIGURE 33.
THE FIRE SUPPRESSION BOTTLE JACK 1L2J1.
(f) PFC  Elrond  installs  the  fire  suppression
system
test
equipment power cable on the source simulator.
(g) He  then  removes  the  center  turret
floor
plate
using
procedures outlined in TM 9-2350-252-20-2.
(h) With the floor plate removed, he can now remove the cap
from diagnostic panel jack J1 (figure 34 on the following page) and
install  the  power  cable  from  the  fire  suppression  system  test
equipment to jack J1.
(i) PFC Elrond turns ON the MASTER POWER switch.
(j) He presses the TEST button on the source simulator and
notes whether the TEST light on the source simulator comes ON.
The
branch of this pathway that he will pursue depends on whether or